| Item information | Value |
|---|---|
| Category: | Type 8026 Flow Meter |
| Sensor type: | Paddle wheel |
| Detection of flow direction: | No |
| Paddle wheel material: | PVDF (Polyvinylidene fluoride) |
| Paddle wheel measuring principle detection: | Hall |
| Paddle wheel type: | Magnetic |
| sensor holder material composition: | Plastics |
| Paddle wheel axle material: | Ceramic |
| Sensor holder material: | PVDF (Polyvinylidene fluoride) |
| Bearing material category: | Technical ceramics |
| Insertion sensor length: | short |
| Bearing material: | Ceramic |
| Dynamic viscosity min.: | 0 cP |
| Dynamic viscosity max.: | 300 cP |
| Flow rate (volume): | Yes |
| Type: | 8026 |
| Flow rate (mass): | No |
| Temperature: | No |
| Density: | No |
| Concentration 1: | No |
| Precision of volume flow rate in relation to reading: | 1 % |
| Electronics body material composition: | 1.4404 (316L) |
| Battery voltage: | No |
| DC voltage min.: | 14 V |
| DC voltage max.: | 36 V |
| Nut material: | PC (polycarbonate) |
| Screws material: | Stainless steel |
| Attachment part material: | PSU (polysulfone)/PPSU (polyphenylsulfone) |
| Cover material: | PPS (polyphenylene sulphide) |
| Protective cover material: | PC (polycarbonate) |
| Temperature medium min: | -15 °C |
| Electronics body material category: | Metals |
| Temperature medium max: | 100 °C |
| Electronics body material: | Stainless steel |
| Nominal pressure (DIN EN 1333): | PN 10 |
| Temperature environment min: | -10 °C |
| Temperature environment max: | 60 °C |
| Sensor/housing seal material: | EPDM (ethylene propylene diene rubber) food quality |
| Seal housing/cover material: | EPDM (Ethylene-propylene-diene rubber) |
| Protective cover seal material: | EPDM (ethylene propylene diene rubber) food quality |
| Medium-contacting parts seal material: | FKM (Fluor rubber) |
| Time dosing: | No |
| Batch dosing: | No |
| Extended diagnosis: | No |
| Continuous measurement: | Yes |
| Volumeter: | Yes |
| Dosing: | No |
| Switch: | No |
| Parametrisation local: | Yes |
| Parametrisation separate: | No |
| Parametrisation fixed: | No |
| Product sub-group: | Flow rate |
| Construction device: | Compact |
| Fitting electronic interface: | Insertion 2 (inch) |
| Electrical connection 1 type: | Plug - M12 |
| Electrical connection 1 quantity: | 1 PCE |
| Electrical connection 1 number of contacts: | 5 PCE |
| Electrical connection seal 1 material: | NBR (nitrile rubber) |
| Output 2 digital transistor connection NPN: | Yes |
| Output 2 digital transistor connection PNP: | Yes |
| Operating supply type: | 2 conductor |
| Digital output 2 transistor contactless: | 0,7 A |
| Output type analog quantity: | 1 |
| Output 1 type analog current: | 4-20 mA |
| Output analogue current functioning principle source: | Yes |
| Output analogue current functioning principle drain: | Yes |
| Electrical connection plate material: | Stainless steel |
| Output 1 digital type: | Transistor |
| Tropical climate version: | Yes |
| Digital output 1 transistor contactless: | 0,7 A |
| Output 1 digital transistor connection NPN: | Yes |
| Output 1 digital transistor connection PNP: | Yes |
| Display type: | no display |
| Protection class measurement device (IP): | IP65/67 |
| Output type analog sinus: | No |
| Output type current modulated according to NAMUR: | No |
| Protection rate measurement device NEMA: | NEMA 4X |
| Electrical connection 1 gender: | male |
| Electrical connection 1 material category: | Light metals |
| Electrical connection 1 material: | Diecast zinc, nickel-plated |
| Output 2 digital type: | Transistor |
Technical Specifications
- Flow rate
- 14,0 V - 36 V
- -15,00 °C - 100,00 °C
- Paddle wheel
- Magnetic
- Transistor
- EPDM (ethylene propylene diene rubber) food quality
- PVDF (Polyvinylidene fluoride)
- FKM (Fluor rubber)
- PVDF (Polyvinylidene fluoride)
Description
The type 8026 insertion flow meter in ELEMENT design is engineered for a broad range of applications — from water supply through wastewater monitoring to chemical processing. It is particularly suited for use in solids-free liquids.
The device is available with 2, 3, or 4 configurable outputs: with one transistor output (NPN) and one 4…20 mA current output (2-wire); with two transistor outputs (NPN/PNP) and one 4…20 mA current output (2-wire); or with two transistor outputs (NPN/PNP) and two 4…20 mA current outputs (3-wire). The measurement signal is converted, displayed in various units of measure when the display/configuration module is plugged in, and the output signals are transmitted via one or two M12 connectors. The transistor outputs can, for example, switch a solenoid valve or trigger an alarm, while the current outputs allow the setup of one or two control loops.
- Up to PN10, meter tube size DN 20…DN 400
- Configurable outputs: one to two transistor outputs and one to two 4…20 mA current outputs
- Removable, backlit display/configuration module showing flow rate and volume via two totalizers
- Automatic calibration via teach-in, all outputs can be tested even without actual flow
Your Benefits
- Worldwide shipping for all valves and measuring instruments
- Large stock levels for many products – just ask us for current lead times
- Spare parts and service kits are also available
- Fast delivery from stock via UPS (parcel) or DSV (pallet), express shipping available on request
- Extensive application know-how built on years of practical experience
- Personal advice on choosing the right component
- Resellers receive volume-based trade discounts on request – just get in touch with us directly
- Large enterprises, public authorities and government bodies can order on account – please contact us via our contact form
Christian Bürkert GmbH & Co. KG, Christian-Bürkert-Straße 13-17, 74653 Ingelfingen, Baden-Württemberg, Deutschland, [email protected], https://www.buerkert.de
Manufacturer according to GPSR
Christian Bürkert GmbH & Co. KG, Christian-Bürkert-Straße13-17, 74653 Ingelfingen, Baden-Württemberg, Deutschland, [email protected], https://www.buerkert.de