| Item information | Value |
|---|---|
| GTIN: | 4030661472522 |
| Category: | AZM300 |
| Version: | AZM300B-I2-ST-1P2P-A-T |
| Length of sensor: | 146 mm |
| Height of sensor: | 55 mm |
| Coding: | Individual coding, multiple teaching |
| Coding level according to EN ISO 14119: | High |
| Item weight: | 0,61 kg |
Schmersal AZM300B-I2-ST-1P2P-A-T – Solenoid interlock of the AZM300 series. It keeps the movable guard locked until the hazardous condition has ended and signals position and locking status to the safety controller. The manufacturer's article number is 103010555, the EAN 4030661472522.
Scope of delivery
Actuator must be ordered separately.
Important note
As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened.
For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used.
For glass and Makrolon doors, the optional mounting kit MS-AZ/AZM300-B1-1 can be used.
Technical data
Safety-related characteristic data (10)
| Standards | EN IEC 61508 / EN ISO 13849-1 |
| Coding level according to EN ISO 14119 | High |
| Short circuit detection | Yes |
| Cross-circuit detection | Yes |
| Category | 4 |
| Mission time | 20 Year(s) |
| Performance Level, up to | e |
| PFD value | 4.50 x 10⁻⁵ |
| PFH value | 5.20 x 10⁻¹⁰ /h |
| Safety Integrity Level (SIL), suitable for applications in | 3 |
Interlocking and actuation (8)
| Holding force FZh in accordance with EN ISO 14119 | 1,150 N |
| Holding force Fmax, maximum | 1,500 N |
| Emergency exit | Yes |
| Number of actuating directions | 3 |
| Angular misalignment between solenoid interlock and actuator, maximum | 2 ° |
| Mechanical lifetime, minimum | 1,000,000 Operations |
| Latching force, adjustable, position 1 | 25 N |
| Latching force, adjustable, position 2 | 50 N |
Contacts and connection (9)
| PIN 1 | A1 Supply voltage UB |
| PIN 2 | X1 Safety input 1 |
| PIN 3 | A2 GND |
| PIN 4 | Y1 Safety output 1 |
| PIN 5 | OUT Diagnostic output |
| PIN 6 | X2 Safety input 2 |
| PIN 7 | Y2 Safety output 2 |
| PIN 8 | IN Solenoid control |
| Termination | Connector M12, 8-pole, A-coded |
Electrical data (37)
| Magnet switch-on time | 100 % |
| Rated insulation voltage Ui | 32 VDC |
| Rated impulse withstand voltage Uimp | 0.8 kV |
| Required rated short-circuit current | 100 A |
| Test pulse duration, maximum | 5 ms |
| Test pulse interval, minimum | 40 ms |
| Protection class | III |
| Current consumption at 24 V | 10 mA |
| Current consumption at 24 V | 5 mA |
| Current consumption with magnet ON, average | 200 mA |
| Current consumption with magnet ON, peak | 350 mA / 200 ms |
| Leakage current Ir, maximum | 0.5 mA |
| No-load supply current I0, typical | 100 mA |
| Operating current | 800 mA |
| Current, Utilisation category DC-12 | 0.05 A |
| Current, Utilisation category DC-12 | 0.25 A |
| Current, Utilisation category DC-13 | 0.05 A |
| Current, Utilisation category DC-13 | 0.25 A |
| Transmitter output RFID, maximum | -6 dBm |
| Duration of risk, maximum | 200 ms |
| Frequency band RFID | 125 kHz |
| Reaction time, switching off safety outputs via actuator, maximum | 100 ms |
| Reaction time, switching off safety outputs via safety inputs, maximum | 1.5 ms |
| Switching frequency, maximum | 0.5 Hz |
| Test pulse duration, maximum | 1 ms |
| Test pulse duration, maximum | 0.5 ms |
| Test pulse interval, minimum | 100 ms |
| Test pulse interval, typical | 1,000 ms |
| Time to readiness, maximum | 5,000 ms |
| Voltage drop Ud, maximum | 2 V |
| Voltage drop Ud, maximum | 2 V |
| Operating voltage | 24 VDC -15 % / +10 % (stabilised PELV power supply) |
| Rated operating voltage | 24 VDC |
| Voltage, Utilisation category DC-12 | 24 VDC |
| Voltage, Utilisation category DC-12 | 24 VDC |
| Voltage, Utilisation category DC-13 | 24 VDC |
| Voltage, Utilisation category DC-13 | 24 VDC |
Indication (1)
| Integral system diagnostics, status | Yes |
Design, material, environment (18)
| Working principle | RFID |
| Housing material | Glass-fibre, reinforced thermoplastic |
| Length of sensor | 146 mm |
| Width of sensor | 87.5 mm |
| Height of sensor | 55 mm |
| Gross weight | 610 g |
| Type of the fixing screws | 2x M6 |
| IP Degree of protection | IP66 / IP69 / IP67 |
| Ambient temperature | +0 ... +60 °C |
| Storage and transport temperature | -10 ... +90 °C |
| Note (Relative humidity) | non-condensing / non-icing |
| Permissible installation altitude above sea level, maximum | 3,000 m |
| Length of sensor chain, maximum | 200 m |
| Assured switching distance "OFF" Sar | 20 mm |
| Assured switching distance "ON" Sao | 1 mm |
| Switch distance, typical | 2 mm |
| Tightening torque of the fixing screws, maximum | 7 Nm |
| Tightening torque of the fixing screws, minimum | 6 Nm |
Standards and approvals (5)
| Standards | EN IEC 60947-5-3 / EN IEC 61508 / EN ISO 13849-1 / EN ISO 14119 |
| Certificates | UKCA / cULus / TÜV / IC / ECOLAB / FCC / ANATEL |
| eCl@ss number, version 12.0 | 27-27-26-03 |
| ETIM number, version 7.0 | EC002593 |
| Coding | Individual coding, multiple teaching |
Weitere Angaben (32)
| Relative humidity, maximum | 93 % |
| Degree of pollution | 3 |
| Overvoltage category | III |
| Design of control elements | short-circuit proof, p-type |
| Design of control elements | short-circuit proof, p-type |
| Classification ZVEI CB24I, Sink | C0 |
| Classification ZVEI CB24I, Sink | C1 |
| Classification ZVEI CB24I, Sink | C1 / C2 |
| Classification ZVEI CB24I, Source | C3 / C2 / C1 |
| Classification ZVEI CB24I, Source | C1 / C2 / C3 |
| Classification ZVEI CB24I, Source | C2 |
| Designation, Diagnostic outputs | OUT |
| Designation, Magnet control | IN |
| Designation, Safety inputs | X1 and X2 |
| Designation, Safety outputs | Y1 and Y2 |
| External wire and device fuse rating | 2 A gG |
| Electrical fuse rating, maximum | 2 A |
| Switching thresholds | -3 V … 5 V (Low) / 15 V … 30 V (High) |
| Switching thresholds | −3 V … 5 V (Low) / 15 V … 30 V (High) |
| Note (Mechanical lifetime) | When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s) |
| Note (switching distance) | All switching distances in accordance EN IEC 60947-5-3 |
| Note (LED switching conditions display) | Error / functional defect: LED red / Operating condition: LED green / Supply voltage UB: LED green |
| Note (length of the sensor chain) | Cable length and cross-section change the voltage drop dependiing on the output current |
| Note (series-wiring) | Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD |
| Number of fail-safe digital outputs | 2 |
| Recommendation (actuator) | AZ/AZM300-B1 |
| Resistance to vibrations | 10 … 150 Hz, amplitude 0.35 mm |
| Restistance to shock | 30 g / 11 ms |
| Actuator monitored | Yes |
| Latching | Yes |
| Safety functions | Yes |
| Series-wiring | Yes |
Delivery time and availability
Many items of this series are available from stock; special versions are built to order by the manufacturer and take correspondingly longer. The delivery time shown in the shop applies to stocked goods and is a guide value. For urgent orders please ask us for the actual delivery time in advance – we will also check whether express shipping is possible.
Your advantage when buying from us
- Authorised Schmersal dealer — genuine products with full manufacturer warranty
- Technical advice from specialists in machine safety
- All safety-related characteristic data documented for your risk assessment
- Matching actuators and accessories from a single source
- A named contact instead of an anonymous ticket system
- Shipping from Germany, delivery throughout Europe
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, 42279 Wuppertal, Nordrhein-Westfalen, Deutschland, [email protected], https://www.schmersal.com
Manufacturer according to GPSR
K.A. Schmersal GmbH & Co. KG, Möddinghofe30, 42279 Wuppertal, Nordrhein-Westfalen, Deutschland, [email protected], https://www.schmersal.com