| Item information | Value |
|---|---|
| Category: | GLL170 |
| Termination: | Cable, 3-wire |
| Adjustment: | Potentiometer |
| Response time: | = 250 µs |
| Item weight: | 94,00 kg |
Features
| Device type | Fiber-optic amplifier | ||||||||||
| Device type detail | Stand-alone | ||||||||||
| Functional principle detail | Depending on the optical fiber cable used | ||||||||||
| Sensing range max. | Depending on the optical fiber cable used | ||||||||||
| |||||||||||
| |||||||||||
| |||||||||||
| |||||||||||
Safety-related parameters
| MTTFD | 760 years |
| DCavg | 0 % |
| TM (mission time) | 20 years |
Electronics
| Supply voltage UB | 10 V DC ... 30 V DC 1) | ||||||||||||||||||||||||||||
| Ripple | = 10 % 2) | ||||||||||||||||||||||||||||
| Current consumption | = 30 mA 3) | ||||||||||||||||||||||||||||
| Protection class | III | ||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||
Mechanics
| Housing | Rectangular | ||||||||||
| Dimensions (W x H x D) | 10 mm x 31.7 mm x 72.5 mm | ||||||||||
| Connection | Cable, 3-wire | ||||||||||
| |||||||||||
| |||||||||||
| Weight | 63 g | ||||||||||
| Maximum tightening torque of the fixing screws | 0.5 Nm | ||||||||||
Ambient data
| Enclosure rating | IP66 (EN 60529) |
| Ambient operating temperature | –25 °C ... +55 °C |
| Ambient temperature, storage | –40 °C ... +70 °C |
| Typ. Ambient light immunity |
Artificial light: = 5,000 lx Sunlight: = 60,000 lx |
| Shock resistance | 50 g, 11 ms (3 positive and 3 negative shocks along X, Y, Z axes, 18 total shocks (EN60068-2-27)) |
| Vibration resistance | 10 Hz ... 55 Hz (Amplitude 1 mm, 3 x 30 min (EN60068-2-6)) |
| Air humidity | 35 % ... 95 %, relative humidity (no condensation) |
| Electromagnetic compatibility (EMC) | EN 60947-5-2 |
| UL File No. | NRKH2.E300503 & NRKH8.E300503 |
| RoHS certificate | ? |
Smart Task
| Timer function |
Deactivated Switch-on delay Off delay Impulse (one shot) |
Certificates
| EU declaration of conformity | ? |
| UK declaration of conformity | ? |
| ACMA declaration of conformity | ? |
| Moroccan declaration of conformity | ? |
| China-RoHS | ? |
| cRUus certificate | ? |
Classifications
| ECLASS 5.0 | 27270905 |
| ECLASS 5.1.4 | 27270905 |
| ECLASS 6.0 | 27270905 |
| ECLASS 6.2 | 27270905 |
| ECLASS 7.0 | 27270905 |
| ECLASS 8.0 | 27270905 |
| ECLASS 8.1 | 27270905 |
| ECLASS 9.0 | 27270905 |
| ECLASS 10.0 | 27270905 |
| ECLASS 11.0 | 27270905 |
| ECLASS 12.0 | 27270905 |
| ETIM 5.0 | EC002651 |
| ETIM 6.0 | EC002651 |
| ETIM 7.0 | EC002651 |
| ETIM 8.0 | EC002651 |
| UNSPSC 16.0901 | 39121528 |
SICK AG, Erwin-Sick-Str. 1, 79183 Waldkirch, Baden-Württemberg, Deutschland, [email protected]
Manufacturer according to GPSR