Siemens 3RA2816-0EW20
function module star-delta (wye-delta), consisting of lateral basic module and two coupling modules, time range 0.05-60 s, 24-240 V AC/DC, 50/60 Hz, varistor for attenuation of the contactor coils integrated, for contactors 3RT20
Technical data
Product data (6)
| Article number | 3RA2816-0EW20 |
| EAN | 4011209824485 |
| Product brand name | SIRIUS |
| Product designation | function module |
| Design of the product | comprising basic module and two coupling modules |
| Product type designation | 3RA28 |
General technical data (32)
| Size of contactor can be combined company-specific | S00, S0, S2, S3 |
| Product component semi-conductor output | No |
| Product extension required remote control | No |
| Product extension optional remote control | No |
| Insulation voltage for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value | 300 V |
| Test voltage for isolation test | 1.5 kV |
| Degree of pollution | 3 |
| Surge voltage resistance rated value | 4 kV |
| Test voltage for surge voltage test | 4 800 V |
| Consumed current at 24 V | 24 mA |
| Consumed current at 240 V | 7 mA |
| Protection class IP of the terminal | IP20 |
| Shock resistance according to IEC 60068-2-27 | 15 g / 11 ms |
| Vibration resistance according to IEC 60068-2-6 | 10 ... 59 Hz: 0.35 mm, 60 ... 150 Hz: 2 g |
| Mechanical service life (operating cycles) typical | 10 000 000 |
| Mechanical service life (operating cycles) with contactor 3R.2 of frame size S00 | 10 000 000 |
| Mechanical service life (operating cycles) with contactor 3R.2 of frame size S0 | 10 000 000 |
| Mechanical service life (operating cycles) with contactor 3R.2 of frame size S2 | 10 000 000 |
| Mechanical service life (operating cycles) with contactor 3R.2 of frame size S3 | 10 000 000 |
| Electrical endurance (operating cycles) at AC-15 at 230 V typical | 100 000 |
| Electrical endurance (operating cycles) with contactor 3R.2 of frame size S00 | 100 000 |
| Electrical endurance (operating cycles) with contactor 3R.2 of frame size S0 | 100 000 |
| Electrical endurance (operating cycles) with contactor 3R.2 of frame size S2 | 100 000 |
| Electrical endurance (operating cycles) with contactor 3R.2 of frame size S3 | 100 000 |
| Adjustable time | 0.5 ... 60 s |
| Relative setting accuracy relating to full-scale value | 15 % |
| Recovery time | 150 ms |
| Reference code according to IEC 81346-2 | K |
| Active principle | electronic |
| Relative repeat accuracy | 1 % |
| Influence of the surrounding temperature | ±1 % |
| Power supply influence | ±2 % |
Product Function (1)
| Product function star-delta circuit | Yes |
Control circuit/ Control (15)
| Type of voltage of the control supply voltage | AC/DC |
| Control supply voltage at AC at 50 Hz rated value | 24 ... 240 V |
| Control supply voltage at AC at 60 Hz rated value | 24 ... 240 V |
| Control supply voltage 1 at AC at 50 Hz | 24 ... 240 V |
| Control supply voltage 1 at AC at 60 Hz | 24 ... 240 V |
| Control supply voltage frequency 1 | 50 ... 60 Hz |
| Control supply voltage at DC rated value | 24 ... 240 V |
| Control supply voltage 1 at DC | 24 ... 240 V |
| Operating range factor control supply voltage rated value at DC initial value | 0.85 |
| Operating range factor control supply voltage rated value at DC full-scale value | 1.1 |
| Operating range factor control supply voltage rated value at AC at 50 Hz initial value | 0.85 |
| Operating range factor control supply voltage rated value at AC at 50 Hz full-scale value | 1.1 |
| Operating range factor control supply voltage rated value at AC at 60 Hz initial value | 0.85 |
| Operating range factor control supply voltage rated value at AC at 60 Hz full-scale value | 1.1 |
| Design of the surge suppressor | with varistor |
Switching Function (36)
| Switching function ON-delay | No |
| Switching function ON-delay/instantaneous contact | No |
| Switching function passing make contact | No |
| Switching function passing make contact/instantaneous contact | No |
| Switching function OFF delay | No |
| Switching function flashing symmetrically with interval start/instantaneous | No |
| Switching function flashing symmetrically with interval start | No |
| Switching function flashing symmetrically with pulse start/instantaneous | No |
| Switching function flashing symmetrically with pulse start | No |
| Switching function flashing asymmetrically with interval start | No |
| Switching function flashing asymmetrically with pulse start | No |
| Switching function constant clock cycle with pulse start | No |
| Switching function constant clock cycle with interval start | No |
| Switching function variably clocked with pulse start | No |
| Switching function variably clocked with interval start | No |
| Switching function star-delta circuit with delay time | No |
| Switching function star-delta circuit | Yes |
| Switching function with control signal additive ON-delay | No |
| Switching function with control signal passing break contact | No |
| Switching function with control signal passing break contact/instantaneous | No |
| Switching function with control signal OFF delay | No |
| Switching function with control signal OFF delay/instantaneous | No |
| Switching function with control signal pulse delayed | No |
| Switching function with control signal pulse delayed/instantaneous | No |
| Switching function with control signal pulse-shaping | No |
| Switching function with control signal pulse-shaping/instantaneous | No |
| Switching function with control signal additive ON-delay/instantaneous | No |
| Switching function with control signal ON-delay/OFF-delay | No |
| Switching function with control signal ON-delay/OFF-delay/instantaneous | No |
| Switching function with control signal passing make contact | No |
| Switching function with control signal passing make contact/instantaneous contact | No |
| Switching function of interval relay with control signal retrotriggerable with deactivated control signal/instantaneous contact | No |
| Switching function of interval relay with control signal retrotriggerable with switched-on control signal | No |
| Switching function of interval relay with control signal retrotriggerable with switched-on control signal/instantaneous contact | No |
| Switching function of interval relay with control signal retriggerable with deactivated control signal | No |
| Design of the control terminal non-floating | No |
Short-circuit protection (1)
| Design of the fuse link for short-circuit protection of the auxiliary switch required | fuse gL/gG: 4 A |
Auxiliary circuit (8)
| Material of switching contacts | AgSnO2 |
| Number of NC contacts delayed switching | 0 |
| Number of NC contacts instantaneous contact | 0 |
| Number of NO contacts delayed switching | 2 |
| Number of NO contacts instantaneous contact | 0 |
| Number of CO contacts delayed switching | 0 |
| Number of CO contacts instantaneous contact | 0 |
| Operating frequency with 3RT2 contactor maximum | 2 500 1/h |
Main circuit (1)
| Type of voltage | AC/DC |
Inputs/ Outputs (2)
| Product function at the relay outputs switchover delayed/without delay | No |
| Product function non-volatile | No |
Electromagnetic compatibility (6)
| EMC immunity according to IEC 61812-1 | Environment A (industrial area) |
| Conducted interference due to burst according to IEC 61000-4-4 | 2 kV network connection / 1 kV control connection |
| Conducted interference due to conductor-earth surge according to IEC 61000-4-5 | 2 kV |
| Conducted interference due to conductor-conductor surge according to IEC 61000-4-5 | 1 kV |
| Field-based interference according to IEC 61000-4-3 | 10 V/m |
| Electrostatic discharge according to IEC 61000-4-2 | 8 kV |
Safety related data (4)
| Category according to EN 954-1 | none |
| Protection class IP on the front according to IEC 60529 | IP20 |
| Touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front |
| Type of insulation | Basic insulation |
Connections/ Terminals (2)
| Product component removable terminal for auxiliary and control circuit | No |
| Type of electrical connection | screw terminal |
Installation/ mounting/ dimensions (20)
| Mounting position | any (like contactor) |
| Fastening method | clip-on |
| Height | 38 mm |
| Width | 45 mm |
| Depth | 74 mm |
| With side-by-side mounting forwards | 0 mm |
| With side-by-side mounting backwards | 0 mm |
| With side-by-side mounting upwards | 0 mm |
| With side-by-side mounting downwards | 0 mm |
| With side-by-side mounting at the side | 0 mm |
| For grounded parts forwards | 0 mm |
| For grounded parts backwards | 0 mm |
| For grounded parts upwards | 0 mm |
| For grounded parts at the side | 0 mm |
| For grounded parts downwards | 0 mm |
| For live parts forwards | 0 mm |
| For live parts backwards | 0 mm |
| For live parts upwards | 0 mm |
| For live parts downwards | 0 mm |
| For live parts at the side | 0 mm |
Ambient conditions (5)
| Installation altitude at height above sea level maximum | 2 000 m |
| Ambient temperature during operation | -25 ... +60 °C |
| Ambient temperature during storage | -40 ... +85 °C |
| Ambient temperature during transport | -40 ... +85 °C |
| Relative humidity during operation | 0 ... 95 % |
Shipping & customs (3)
| Weight | 0,216 kg |
| Customs tariff number | 85364900 |
| Country of origin | CZ |
Product benefits
- Genuine Siemens parts – fit and ratings match the contactor
- Wearing parts and spares keep existing plants running instead of replacing them
- Plug-on and add-on parts need no special tool
- Clear assignment by series and size – the datasheet values are shown with every article
- Still available for the older 3RT1 and 3RH1 series as well
Your advantages when buying from us
- Worldwide shipping of all switching and control devices
- Large stock levels for many products – just ask us for current delivery times
- Accessories, spare parts and matching modules are available as well
- Fast delivery from stock by UPS (parcel) or DSV (pallet), express shipping on request
- Extensive application know-how from many years of practice
- Personal advice on choosing the right component
- Dealers receive volume-based trade discounts on request – talk to us directly
- Large companies, authorities and public bodies can order on account – please enquire via our contact form
Siemens
Manufacturer according to GPSR
Siemens