| Insulation voltage with degree of pollution 3 at AC rated value |
500 V |
| Surge voltage resistance rated value |
6 kV |
| Protection class IP on the front |
IP20 |
| Mechanical service life (operating cycles) typical |
10 000 000 |
| Electrical endurance (operating cycles) at AC-15 at 230 V typical |
200 000 |
| Number of NC contacts for auxiliary contacts instantaneous contact |
0 |
| Number of NO contacts for auxiliary contacts instantaneous contact |
2 |
| Number of CO contacts of auxiliary contacts instantaneous contact |
0 |
| Operational current of auxiliary contacts at AC-12 at 24 V |
10 A |
| Operational current of auxiliary contacts at AC-12 at 230 V |
10 A |
| Operational current of auxiliary contacts at AC-14 at 125 V |
6 A |
| Operational current of auxiliary contacts at AC-14 at 250 V |
6 A |
| Operational current of auxiliary contacts at AC-12 maximum |
10 A |
| Operational current of auxiliary contacts at AC-15 at 24 V |
6 A |
| Operational current of auxiliary contacts at AC-15 at 230 V |
6 A |
| Operational current of auxiliary contacts at AC-15 at 400 V |
3 A |
| Operational current of auxiliary contacts at DC-12 at 24 V |
10 A |
| Operational current of auxiliary contacts at DC-12 at 110 V |
3 A |
| Operational current of auxiliary contacts at DC-12 at 220 V |
1 A |
| Operational current with 2 current paths in series at DC-12 at 24 V rated value |
10 A |
| Operational current with 2 current paths in series at DC-12 at 60 V rated value |
10 A |
| Operational current with 2 current paths in series at DC-12 at 110 V rated value |
4 A |
| Operational current with 2 current paths in series at DC-12 at 220 V rated value |
2 A |
| Operational current with 2 current paths in series at DC-12 at 440 V rated value |
1.3 A |
| Operational current with 3 current paths in series at DC-12 at 24 V rated value |
10 A |
| Operational current with 3 current paths in series at DC-12 at 60 V rated value |
10 A |
| Operational current with 3 current paths in series at DC-12 at 110 V rated value |
10 A |
| Operational current with 3 current paths in series at DC-12 at 220 V rated value |
3.6 A |
| Operational current with 3 current paths in series at DC-12 at 440 V rated value |
2.5 A |
| Operational current with 2 current paths in series at DC-13 at 24 V rated value |
10 A |
| Operational current with 2 current paths in series at DC-13 at 60 V rated value |
3.5 A |
| Operational current with 2 current paths in series at DC-13 at 110 V rated value |
1.3 A |
| Operational current with 2 current paths in series at DC-13 at 220 V rated value |
0.9 A |
| Operational current with 2 current paths in series at DC-13 at 440 V rated value |
0.2 A |
| Operational current with 3 current paths in series at DC-13 at 24 V rated value |
10 A |
| Operational current with 3 current paths in series at DC-13 at 60 V rated value |
4.7 A |
| Operational current with 3 current paths in series at DC-13 at 110 V rated value |
3 A |
| Operational current with 3 current paths in series at DC-13 at 220 V rated value |
1.2 A |
| Operational current with 3 current paths in series at DC-13 at 440 V rated value |
0.5 A |
| Operational current of auxiliary contacts at DC-13 at 24 V |
6 A |
| Operational current of auxiliary contacts at DC-13 at 48 V |
2 A |
| Operational current of auxiliary contacts at DC-13 at 60 V |
2 A |
| Operational current of auxiliary contacts at DC-13 at 110 V |
1 A |
| Operational current of auxiliary contacts at DC-13 at 125 V |
0.9 A |
| Operational current of auxiliary contacts at DC-13 at 220 V |
0.3 A |
| Operational current of auxiliary contacts at DC-13 at 250 V |
0.3 A |
| Design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 V |
C characteristic: 10 A; 0.4 kA |
| Contact reliability of auxiliary contacts |
1 faulty switching per 100 million (17 V, 1 mA) |