| Item information | Value |
|---|---|
| Category: | SIRIUS 3RT power contactors, size S2 |
Siemens power contactor, AC-3e/AC-3, 41 A, 18.5 kW / 400 V, 3-pole, auxiliary contacts: 2 NO + 2 NC, screw terminal, size: S2
power contactor, AC-3e/AC-3, 41 A, 18.5 kW / 400 V, 3-pole, auxiliary contacts: 2 NO + 2 NC, screw terminal, size: S2
Available variants
- Coil voltage: 24 V, 42 V, 110 V, 48 V, 230 V, 220 V, 240 V, 400 V
- Frequency: 50 Hz, 50/60 Hz
- Version: removable auxiliary switch, captive auxiliary switch
Technical data
Product data (5)
| Article number | 3RT2035-1AB04 |
| EAN | 4011209939004 |
| Product brand name | SIRIUS |
| Product designation | Power contactor |
| Product type designation | 3RT2 |
General technical data (18)
| Size of contactor | S2 |
| Product extension function module for communication | No |
| Product extension auxiliary switch | No |
| Power loss [W] for rated value of the current at AC in hot operating state | 6.6 W |
| Power loss [W] for rated value of the current at AC in hot operating state per pole | 2.2 W |
| Power loss [W] for rated value of the current without load current share typical | 6 W |
| Type of calculation of power loss current-dependent | quadratic |
| Insulation voltage of main circuit with degree of pollution 3 rated value | 690 V |
| Insulation voltage of auxiliary circuit with degree of pollution 3 rated value | 690 V |
| Surge voltage resistance of main circuit rated value | 6 kV |
| Surge voltage resistance of auxiliary circuit rated value | 6 kV |
| Maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1 | 400 V |
| Shock resistance at rectangular impulse at AC | 9.8 g / 5 ms, 6.5 g / 10 ms |
| Shock resistance with sine pulse at AC | 15.3 g / 5 ms, 10.1 g / 10 ms |
| Mechanical service life (operating cycles) of contactor typical | 10 000 000 |
| Mechanical service life (operating cycles) of the contactor with added electronically optimized auxiliary switch block typical | 5 000 000 |
| Mechanical service life (operating cycles) of the contactor with added auxiliary switch block typical | 10 000 000 |
| Reference code according to IEC 81346-2 | Q |
Ambient conditions (5)
| Installation altitude at height above sea level maximum | 2 000 m |
| Ambient temperature during operation | -25 ... +60 °C |
| Ambient temperature during storage | -55 ... +80 °C |
| Relative humidity minimum | 10 % |
| Relative humidity at 55 °C according to IEC 60068-2-30 maximum | 95 % |
Main circuit (93)
| Number of poles for main current circuit | 3 |
| Number of NO contacts for main contacts | 3 |
| Number of NC contacts for main contacts | 0 |
| Operating voltage at AC-3 rated value maximum | 690 V |
| Operating voltage at AC-3e rated value maximum | 690 V |
| Operational current at AC-1 at 400 V at ambient temperature 40 °C rated value | 60 A |
| At AC-1 up to 690 V at ambient temperature 40 °C rated value | 60 A |
| At AC-1 up to 690 V at ambient temperature 60 °C rated value | 55 A |
| At AC-3 at 400 V rated value | 41 A |
| At AC-3 at 500 V rated value | 41 A |
| At AC-3 at 690 V rated value | 24 A |
| At AC-3e at 400 V rated value | 41 A |
| At AC-3e at 500 V rated value | 41 A |
| At AC-3e at 690 V rated value | 24 A |
| At AC-3e at AC-4 at 400 V rated value | 35 A |
| At AC-3e at AC-5a up to 690 V rated value | 52.8 A |
| At AC-3e at AC-5b up to 400 V rated value | 33.2 A |
| At AC-6a up to 230 V for current peak value n=20 rated value | 36.5 A |
| At AC-6a up to 400 V for current peak value n=20 rated value | 36.5 A |
| At AC-6a up to 500 V for current peak value n=20 rated value | 36.5 A |
| At AC-6a up to 690 V for current peak value n=20 rated value | 24 A |
| At AC-6a up to 230 V for current peak value n=30 rated value | 24.2 A |
| At AC-6a up to 400 V for current peak value n=30 rated value | 24.2 A |
| At AC-6a up to 500 V for current peak value n=30 rated value | 24.2 A |
| At AC-6a up to 690 V for current peak value n=30 rated value | 24 A |
| Minimum cross-section in main circuit at maximum AC-1 rated value | 16 mm² |
| Operational current for approx. 200000 operating cycles at AC-4 at 400 V rated value | 22 A |
| Operational current for approx. 200000 operating cycles at AC-4 at 690 V rated value | 18.5 A |
| At 1 current path at DC-1 at 24 V rated value | 55 A |
| At 1 current path at DC-1 at 60 V rated value | 23 A |
| At 1 current path at DC-1 at 110 V rated value | 4.5 A |
| At 1 current path at DC-1 at 220 V rated value | 1 A |
| At 1 current path at DC-1 at 440 V rated value | 0.4 A |
| At 1 current path at DC-1 at 600 V rated value | 0.25 A |
| With 2 current paths in series at DC-1 at 24 V rated value | 55 A |
| With 2 current paths in series at DC-1 at 60 V rated value | 45 A |
| With 2 current paths in series at DC-1 at 110 V rated value | 45 A |
| With 2 current paths in series at DC-1 at 220 V rated value | 5 A |
| With 2 current paths in series at DC-1 at 440 V rated value | 1 A |
| With 2 current paths in series at DC-1 at 600 V rated value | 0.8 A |
| With 3 current paths in series at DC-1 at 24 V rated value | 55 A |
| With 3 current paths in series at DC-1 at 60 V rated value | 55 A |
| With 3 current paths in series at DC-1 at 110 V rated value | 55 A |
| With 3 current paths in series at DC-1 at 220 V rated value | 45 A |
| With 3 current paths in series at DC-1 at 440 V rated value | 2.9 A |
| With 3 current paths in series at DC-1 at 600 V rated value | 1.4 A |
| At 1 current path at DC-3 at DC-5 at 24 V rated value | 35 A |
| At 1 current path at DC-3 at DC-5 at 60 V rated value | 6 A |
| At 1 current path at DC-3 at DC-5 at 220 V rated value | 1 A |
| At 1 current path at DC-3 at DC-5 at 440 V rated value | 0.1 A |
| At 1 current path at DC-3 at DC-5 at 600 V rated value | 0.06 A |
| With 2 current paths in series at DC-3 at DC-5 at 24 V rated value | 55 A |
| With 2 current paths in series at DC-3 at DC-5 at 60 V rated value | 45 A |
| With 2 current paths in series at DC-3 at DC-5 at 110 V rated value | 25 A |
| With 2 current paths in series at DC-3 at DC-5 at 220 V rated value | 5 A |
| With 2 current paths in series at DC-3 at DC-5 at 440 V rated value | 0.27 A |
| With 2 current paths in series at DC-3 at DC-5 at 600 V rated value | 0.16 A |
| With 3 current paths in series at DC-3 at DC-5 at 24 V rated value | 55 A |
| With 3 current paths in series at DC-3 at DC-5 at 60 V rated value | 55 A |
| With 3 current paths in series at DC-3 at DC-5 at 110 V rated value | 55 A |
| With 3 current paths in series at DC-3 at DC-5 at 220 V rated value | 25 A |
| With 3 current paths in series at DC-3 at DC-5 at 440 V rated value | 0.6 A |
| With 3 current paths in series at DC-3 at DC-5 at 600 V rated value | 0.35 A |
| Operating power at AC-2 at 400 V rated value | 18.5 kW |
| At AC-3 at 230 V rated value | 11 kW |
| At AC-3 at 400 V rated value | 18.5 kW |
| At AC-3 at 500 V rated value | 22 kW |
| At AC-3 at 690 V rated value | 22 kW |
| At AC-3e at 230 V rated value | 11 kW |
| At AC-3e at 400 V rated value | 18.5 kW |
| At AC-3e at 500 V rated value | 22 kW |
| At AC-3e at 690 V rated value | 22 kW |
| Operating power for approx. 200000 operating cycles at AC-4 at 400 V rated value | 11.6 kW |
| Operating power for approx. 200000 operating cycles at AC-4 at 690 V rated value | 16.8 kW |
| Operating apparent power at AC-6a up to 230 V for current peak value n=20 rated value | 14.5 kVA |
| Operating apparent power at AC-6a up to 400 V for current peak value n=20 rated value | 25.2 kVA |
| Operating apparent power at AC-6a up to 500 V for current peak value n=20 rated value | 31.6 kVA |
| Operating apparent power at AC-6a up to 690 V for current peak value n=20 rated value | 28.6 kVA |
| Operating apparent power at AC-6a up to 230 V for current peak value n=30 rated value | 9.6 kVA |
| Operating apparent power at AC-6a up to 400 V for current peak value n=30 rated value | 16.8 kVA |
| Operating apparent power at AC-6a up to 500 V for current peak value n=30 rated value | 21 kVA |
| Operating apparent power at AC-6a up to 690 V for current peak value n=30 rated value | 28.6 kVA |
| Short-time withstand current in cold operating state up to 40 °C limited to 1 s switching at zero current maximum | 843 A; Use minimum cross-section acc. to AC-1 rated value |
| Short-time withstand current in cold operating state up to 40 °C limited to 5 s switching at zero current maximum | 596 A; Use minimum cross-section acc. to AC-1 rated value |
| Short-time withstand current in cold operating state up to 40 °C limited to 10 s switching at zero current maximum | 400 A; Use minimum cross-section acc. to AC-1 rated value |
| Short-time withstand current in cold operating state up to 40 °C limited to 30 s switching at zero current maximum | 241 A; Use minimum cross-section acc. to AC-1 rated value |
| Short-time withstand current in cold operating state up to 40 °C limited to 60 s switching at zero current maximum | 196 A; Use minimum cross-section acc. to AC-1 rated value |
| No-load switching frequency at AC | 5 000 1/h |
| Operating frequency at AC-1 maximum | 1 200 1/h |
| Operating frequency at AC-2 maximum | 750 1/h |
| Operating frequency at AC-3 maximum | 1 000 1/h |
| At AC-3e maximum | 1 000 1/h |
| At AC-3e at AC-4 maximum | 300 1/h |
Control circuit/ Control (11)
| Type of voltage of the control supply voltage | AC |
| Control supply voltage at AC at 50 Hz rated value | 24 V |
| Operating range factor control supply voltage rated value of magnet coil at AC at 50 Hz | 0.8 ... 1.1 |
| Apparent pick-up power of magnet coil at AC at 50 Hz | 190 VA |
| Inductive power factor with closing power of the coil at 50 Hz | 0.72 |
| Apparent holding power of magnet coil at AC at 50 Hz | 16 VA |
| Inductive power factor with the holding power of the coil at 50 Hz | 0.37 |
| Closing delay at AC | 10 ... 80 ms |
| Opening delay at AC | 10 ... 18 ms |
| Arcing time | 10 ... 20 ms |
| Control version of the switch operating mechanism | Standard A1 - A2 |
Auxiliary circuit (22)
| Number of NC contacts for auxiliary contacts instantaneous contact | 2 |
| Number of NO contacts for auxiliary contacts instantaneous contact | 2 |
| Operational current at AC-12 maximum | 10 A |
| Operational current at AC-15 at 230 V rated value | 6 A |
| Operational current at AC-15 at 400 V rated value | 3 A |
| Operational current at AC-15 at 500 V rated value | 2 A |
| Operational current at AC-15 at 690 V rated value | 1 A |
| Operational current at DC-12 at 24 V rated value | 10 A |
| Operational current at DC-12 at 48 V rated value | 6 A |
| Operational current at DC-12 at 60 V rated value | 6 A |
| Operational current at DC-12 at 110 V rated value | 3 A |
| Operational current at DC-12 at 125 V rated value | 2 A |
| Operational current at DC-12 at 220 V rated value | 1 A |
| Operational current at DC-12 at 600 V rated value | 0.15 A |
| Operational current at DC-13 at 24 V rated value | 6 A |
| Operational current at DC-13 at 48 V rated value | 2 A |
| Operational current at DC-13 at 60 V rated value | 2 A |
| Operational current at DC-13 at 110 V rated value | 1 A |
| Operational current at DC-13 at 125 V rated value | 0.9 A |
| Operational current at DC-13 at 220 V rated value | 0.3 A |
| Operational current at DC-13 at 600 V rated value | 0.1 A |
| Contact reliability of auxiliary contacts | 1 faulty switching per 100 million (17 V, 1 mA) |
UL/CSA ratings (9)
| Full-load current (FLA) for 3-phase AC motor at 480 V rated value | 40 A |
| Full-load current (FLA) for 3-phase AC motor at 600 V rated value | 41 A |
| For single-phase AC motor at 110/120 V rated value | 3 hp |
| For single-phase AC motor at 230 V rated value | 7.5 hp |
| For 3-phase AC motor at 200/208 V rated value | 10 hp |
| For 3-phase AC motor at 220/230 V rated value | 15 hp |
| For 3-phase AC motor at 460/480 V rated value | 30 hp |
| For 3-phase AC motor at 575/600 V rated value | 40 hp |
| Contact rating of auxiliary contacts according to UL | A600 / Q600 |
Short-circuit protection (4)
| Design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 V | C characteristic: 10 A; 0.4 kA |
| For short-circuit protection of the main circuit with type of coordination 1 required | gG: 160 A (690 V, 100 kA), aM: 80 A (690 V, 100 kA), BS88: 125 A (415 V, 80 kA) |
| For short-circuit protection of the main circuit with type of coordination 2 required | gG: 80 A (690 V, 100 kA), aM: 50 A (690 V, 100 kA), BS88: 63 A (415 V, 80 kA) |
| For short-circuit protection of the main circuit for short-circuit protection of the auxiliary switch required | gG: 10 A (500 V, 1 kA) |
Installation/ mounting/ dimensions (18)
| Mounting position | +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface |
| Fastening method side-by-side mounting | Yes |
| Fastening method | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715 |
| Height | 114 mm |
| Width | 55 mm |
| Depth | 174 mm |
| With side-by-side mounting forwards | 10 mm |
| With side-by-side mounting upwards | 10 mm |
| With side-by-side mounting downwards | 10 mm |
| With side-by-side mounting at the side | 0 mm |
| For grounded parts forwards | 10 mm |
| For grounded parts upwards | 10 mm |
| For grounded parts at the side | 6 mm |
| For grounded parts downwards | 10 mm |
| For live parts forwards | 10 mm |
| For live parts upwards | 10 mm |
| For live parts downwards | 10 mm |
| For live parts at the side | 6 mm |
Connections/ Terminals (15)
| Type of electrical connection for main current circuit | screw-type terminals |
| Type of electrical connection for auxiliary and control circuit | screw-type terminals |
| Type of electrical connection at contactor for auxiliary contacts | Screw-type terminals |
| Type of electrical connection of magnet coil | screw terminal |
| For main contacts solid or stranded | 2x (1 ... 35 mm²), 1x (1 ... 50 mm²) |
| For main contacts finely stranded with core end processing | 2x (1 ... 25 mm²), 1x (1 ... 35 mm²) |
| For main contacts for AWG cables for main contacts | 2x (18 ... 2), 1x (18 ... 1) |
| Connectable conductor cross-section for main contacts finely stranded with core end processing | 1 ... 35 mm² |
| Connectable conductor cross-section for auxiliary contacts solid or stranded | 0.5 ... 2.5 mm² |
| Connectable conductor cross-section for auxiliary contacts finely stranded with core end processing | 0.5 ... 2.5 mm² |
| For auxiliary contacts solid or stranded | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
| For auxiliary contacts finely stranded with core end processing | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
| For auxiliary contacts for AWG cables for auxiliary contacts | 2x (20 ... 16), 2x (18 ... 14) |
| AWG number as coded connectable conductor cross section for main contacts | 18 ... 1 |
| AWG number as coded connectable conductor cross section for auxiliary contacts | 20 ... 14 |
Safety related data (15)
| Product function mirror contact according to IEC 60947-4-1 | Yes |
| Product function positively driven operation according to IEC 60947-5-1 | No |
| Product function suitable for safety function | Yes |
| Suitability for use safety-related switching OFF | Yes |
| Service life maximum | 20 a |
| Test wear-related service life necessary | Yes |
| Proportion of dangerous failures with low demand rate according to SN 31920 | 40 % |
| Proportion of dangerous failures with high demand rate according to SN 31920 | 73 % |
| B10 value with high demand rate according to SN 31920 | 1 000 000 |
| Failure rate [FIT] with low demand rate according to SN 31920 | 100 FIT |
| Device type according to ISO 13849-1 | 3 |
| Overdimensioning according to ISO 13849-2 necessary | Yes |
| Safety device type according to IEC 61508-2 | Type A |
| Protection class IP on the front according to IEC 60529 | IP20 |
| Touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front |
Shipping & customs (3)
| Weight | 1,041 kg |
| Customs tariff number | 85364190 |
| Country of origin | Germany |
Product benefits
- Proven SIRIUS 3RT range from Siemens – available worldwide and maintained over decades
- Consistent modular system: auxiliary switches, surge suppressors and link modules fit across sizes
- Screw or spring-loaded terminals – spring-loaded saves assembly time and is vibration-proof
- Versions with electronic operating mechanism reduce holding power and work over a wide voltage range
- Approvals to IEC and UL/CSA, so the same plant can be operated in Europe and North America
Your advantages when buying from us
- Worldwide shipping of all switching and control devices
- Large stock levels for many products – just ask us for current delivery times
- Accessories, spare parts and matching modules are available as well
- Fast delivery from stock by UPS (parcel) or DSV (pallet), express shipping on request
- Extensive application know-how from many years of practice
- Personal advice on choosing the right component
- Dealers receive volume-based trade discounts on request – talk to us directly
- Large companies, authorities and public bodies can order on account – please enquire via our contact form
Siemens
Manufacturer according to GPSR
Siemens