Product Description
Turck WIM100-Q25L-LIU5X2-H1141 Magnetically actuated linear position sensor
The Turck WIM100-Q25L-LIU5X2-H1141 is a magnetically actuated linear position sensor. Measuring principle electromagnetic, measuring range up to 100 mm, design profile, output signal analog output, connection via connector, operating voltage 15…30 VDC, protection class IP67, housing made of aluminium/plastic. Ident no. 1536630, EAN 4047101200539.
Features
- Rectangular, aluminum/plastic
- Versatile mounting options
- Measuring range indication via LED
- Immune to external magnetic fields
- Extremely short blind zones
- 4-wire, 15…30 VDC
- Analog output
- 0…10 V and 4…20 mA
- Connector, M12 × 1
Technical data
Electrical data (7)
| Output function |
4-pin, Analog output |
| Short-circuit protection |
yes |
| Wire break/reverse polarity protection |
yes/Complete |
| Current consumption |
< 50 mA |
| Isolation test voltage |
≤ 0,5 kV |
| Residual ripple |
≤ 10 % U ss |
| Sample rate |
200 Hz |
Mechanical data (7)
| Design |
Profile, Q25L |
| Construction type designation |
Q25L |
| Dimensions |
141 mm x 35 mm x 25 mm |
| Housing material |
Aluminum/plastic, PA6-GF30 |
| Active area material |
Plastic, PA6-GF30 |
| Electrical connection |
Connector, M12 x 1 |
| Number of pins |
4 |
Ambient conditions (5)
| Ambient temperature |
-25...+75 °C |
| Pollution degree |
3 |
| Shock resistance |
30 g (11 ms) |
| Vibration resistance |
55 Hz (1 mm) |
| Protection class |
IP67 |
Outputs (4)
| Current output |
4…20 mA |
| Voltage output |
0…10 V |
| Load resistance current output |
≤0,4 kΩ |
| Load resistance voltage output |
≥4,7 kΩ |
Accuracy/deviation (4)
| Resolution |
0.1 mm/10 bit |
| Linearity deviation |
1 % |
| Repeat accuracy |
≤0.1% of measuring range IA - BI depending on positioning element |
| Temperature drift |
≤ ±0,006 %/K |
Tests/approvals (2)
| UL registration number |
E210608 |
| MTTF |
131 years acc. to SN 29500 (Ed. 99) 40 °C |
Displays/controls (2)
| Measuring range display |
LED, yellow, positioning element in measuring range yellow flashing, no positioning element in measuring range after power reset |
| Power-on indication |
LED, Green |
General data (1)
| Measuring principle |
Magnetic |
Detection area/measuring range (1)
Power supply (1)
| Operating voltage UB |
15…30 VDC |
Other properties (1)
Delivery time and availability
For urgent orders please ask us for the exact delivery time in advance; on request we check express shipping.
Your Benefits With Us
- Worldwide shipping of all Turck items
- Large stock levels for many products – current lead time available on request
- Positioning elements, process adapters, antennas and connection cables available on request
- Fast shipping via UPS (parcel) or freight forwarder (pallets), express delivery available on request
- Extensive hands-on application know-how
- Personal advice on selecting the right component
- Resellers receive volume-based discounts on request