| Item information | Value |
|---|---|
| GTIN: | 4011209878099 |
| Category: | 3SE5 position switches, plastic enclosure 40 mm acc. to EN 50041 |
| Switching principle: | snap-action contacts |
| Product designation: | Mechanical safety switches |
| Design of the actuating element: | Other, without, basic switch |
| Ambient temperature during operation: | -25 ... +60 °C |
| Protection class IP: | IP66/IP67 |
| Width of the sensor: | 40 mm |
| Number of NC contacts for auxiliary contacts: | 2 |
| Number of NO contacts for auxiliary contacts: | 1 |
| Type of electrical connection: | screw terminal |
| Material of the enclosure: | plastic |
| Cable entry type: | 1x (M20 x 1.5) |
| Item weight: | 0,10 kg |
Siemens 3SE5132-1LA00
Basic switch for position switch 3SE51 Plastic enclosure 40 mm according to EN 50041 Device connection 1 x (M20 x 1.5) with 2 LEDs, yellow/green, 24 V DC 1 NO/2 NC slow-action contacts without actuator head
Technical data
Product data (7)
| Article number | 3SE5132-1LA00 |
| EAN | 4011209878099 |
| Product brand name | SIRIUS |
| Product designation | Mechanical safety switches |
| Product type designation | 3SE5 |
| Manufacturer's article number of the supplied switching contacts | 3SE5000-0LA00 |
| Manufacturer's article number of the supplied empty enclosure with cover | 3SE5132-0AA00 |
General technical data (20)
| Product function positive opening | Yes |
| Insulation voltage rated value | 400 V |
| Degree of pollution | class 3 |
| Surge voltage resistance rated value | 6 kV |
| Protection class IP | IP66/IP67 |
| Shock resistance according to IEC 60068-2-27 | 30 g / 11 ms |
| Vibration resistance according to IEC 60068-2-6 | 0.35 mm/5 g |
| Mechanical service life (operating cycles) typical | 15 000 000 |
| Thermal current | 10 A |
| Reference code according to IEC 81346-2 | B |
| Continuous current of the C characteristic MCB | 1 A; for a short-circuit current smaller than 400 A |
| Continuous current of the quick DIAZED fuse link | 10 A; for a short-circuit current smaller than 400 A |
| Continuous current of the DIAZED fuse link gG | 6 A |
| Active principle | mechanical |
| Repeat accuracy | 0.05 mm |
| Substance Prohibitance (day/month/year) | 07/01/2006 |
| SVHC substance name | Imidazolidine-2-thione (2-imidazoline-2-thiol) CAS-No. 96-45-7 |
| Minimum actuating force in directions of actuation | 20 N |
| Length of the sensor | 85.7 mm |
| Width of the sensor | 40 mm |
Ambient conditions (3)
| Ambient temperature during operation | -25 ... +60 °C |
| Ambient temperature during storage | -40 ... +90 °C |
| Explosion protection category for dust | none |
Main circuit (4)
| Design of the switching contact | mechanical |
| Number of NC contacts for auxiliary contacts | 2 |
| Number of NO contacts for auxiliary contacts | 1 |
| Operational current at DC-13 at 24 V rated value | 3 A |
Enclosure (4)
| Design of the housing | block, narrow |
| Material of the enclosure | plastic |
| Coating of the enclosure | Other types |
| Design of the housing according to standard | Yes |
Drive Head (5)
| Design of the actuating element | Other, without, basic switch |
| Design of the switching function | Positive opening with appropriate positive opening actuator head |
| Circuit principle | snap-action contacts |
| Number of switching contacts safety-related | 2 |
| Cable entry type | 1x (M20 x 1.5) |
Installation/ mounting/ dimensions (2)
| Mounting position | any |
| Fastening method | screw fixing |
Connections/ Terminals (5)
| Type of electrical connection | screw terminal |
| Type of connectable conductor cross-sections solid | 1x (0.5 ... 1.5 mm²), 2x (0.5 ... 0.75 mm²) |
| Type of connectable conductor cross-sections finely stranded with core end processing | 1x (0.5 ... 1.5 mm²), 2x (0.5 ... 0.75 mm²) |
| Type of connectable conductor cross-sections for AWG cables solid | 1x (20 ... 16), 2x (20 ... 18) |
| Type of connectable conductor cross-sections for AWG cables stranded | 1x (20 ... 16), 2x (20 ... 18) |
Supply voltage (3)
| Type of voltage of the supply voltage of the optional LED display | DC |
| Supply voltage of LED | 24 V |
| Design of the interface for safety-related communication | without |
Communication/ Protocol (1)
| Design of the interface | without |
Safety related data (9)
| Product function suitable for safety function | Yes |
| Service life maximum | 20 a |
| Test wear-related service life necessary | Yes |
| Proportion of dangerous failures with low demand rate according to SN 31920 | 20 % |
| Proportion of dangerous failures with high demand rate according to SN 31920 | 20 % |
| B10 value with high demand rate according to SN 31920 | 10 000 000 |
| Failure rate [FIT] with low demand rate according to SN 31920 | 100 FIT |
| Device type according to ISO 13849-1 | 3 |
| Safety device type according to IEC 61508-2 | A |
Shipping & customs (4)
| Weight | 0,096 kg |
| Customs tariff number | 85365080 |
| Country of origin | Germany |
| Export control | AL: N / ECCN: N |
Your benefits
- Modular design: many variants from a few basic components, actuator heads and contact blocks individually replaceable
- Switching points and mounting acc. to EN 50047 and EN 50041
- Optionally with LED status display and M12 connector for fast connection
- Suitable up to PL e or SIL 3 with the corresponding switch configuration
- Approved worldwide (IEC, UL)
Siemens
Manufacturer according to GPSR
Siemens