Product Description
Turck TBEN-L4-16DXN Field logic controller
The Turck TBEN-L4-16DXN is a field logic controller. Signal type digital output, Digital input/output, Digital input, 16 channels, fieldbus CC-Link IE Field Basic, EtherNet/IP, Modbus TCP, PROFINET, for Zone 2, Zone 22, transmission rate 10/100 Mbit/s, protection class IP65/IP67/IP69K, connection via m12, ambient temperature from -40 °C. Ident no. 6814064, EAN 4047101341454.
Features
- PROFINET device, EtherNet/IP device, Modbus TCP server, CC-Link IE field basic
- Integrated Ethernet switch
- Supports 10 Mbps/100 Mbps
- 2 × M12, 4-pin, D-coded, Ethernet fieldbus connection
- PROFINET S2 system redundancy
- Fibre-glass reinforced housing
- Shock and vibration tested
- Fully potted module electronics
- Protection classes IP65, IP67, IP69K
- 4-pin 7/8″ male connector for power supply
- Galvanically isolated voltage groups
- ATEX zone 2/22
- CCC-Ex
- Input diagnostics per port
- Max. 1 A per output
- Output diagnostics per channel
- Two freely selectable digital channels per port
- Programmable ARGEE Description Ethernet link (100 Mbps) Ethernet communication (100 Mbps) Ethernet link (10 Mbps) Ethernet communication (10 Mbps) No Ethernet link Active connection to a master Steady flashing: Ready for operation Sequence of 3 flashes in 2 seconds: FLC/ARGEE active IP address conflict or Restore mode or Modbus timeout Blink/Wink command active Autonegotiation and/or waiting for DHCP/Boot-P addressing Power off No diagnostics available Diagnostics available Undervoltage diagnosis response is parameter dependent Cyclical IO data exchange Cyclical IO data exchange, diagnostics available Discovery mode active Discovery mode active, diagnostics available ge = "red" V1 and V2 power supply OK V2 power supply off or V2 undervoltage V1 power supply off or V1 undervoltage ge = "green" V1 and V2 power supply OK V2 power supply off or V2 undervoltage V1 power supply off or V1 undervoltage Description Input or output active Output active with overload/ short circuit Power overload at the corresponding port. Both port LEDs are flashing. Input or output inactive ble, 7/8″ female connector, straight, 4-pin to ctor, straight, 4-pin, cable length: 2 m, jacket ay ble, 7/8” connector, straight, 4-pin to 7/8” , straight, 4-pin, cable length: 2 m, jacket ellow; other cable lengths and qualities ww.turck.com M12 female connector, straight, 3-pin to M12 straight, 3-pin; cable length: 2 m, jacket ack; cULus approval M12 female connector, angled, 3-pin to M12 straight, 3-pin; cable length: 2 m, jacket ack; cULus approval M12 female connector, straight, 4-pin to M12 straight, 4-pin; cable length: 2 m, jacket ack; cULus approval M12 female connector, angled, 4-pin to M12 straight, 4-pin, cable length: 2 m, jacket ack; cULus approval M12 female connector, angled, 5-pin to M12 straight, 5-pin; cable length: 2 m, jacket ack; cULus approval M12 female connector, straight, 5-pin to M12 straight, 5-pin; cable length: 2 m, jacket ack; cULus approval stems — Y-splitter with cable, M12 male ht, 4-pin — 2 × M12 female connector, straight, h: 1 m, jacket material: PUR, black sor cordset, extension cable, M12 female ht, 3-pin, M12 male connector, straight, 3-pin, le length: 2 m, cable jacket PVC, gray, other sor cordset, extension cable, M12 female ht, 4-pin, M12 male connector, straight, 4-pin, le length: 2 m, cable jacket PVC, gray, other sor cordset, extension cable, M12 female ht, 5-pin, M12 male connector, straight, 5-pin, le length: 2 m, cable jacket PVC, gray, other al Ethernet, M12 male connector, D-coded, male connector, straight, cable length: 2 m, UR, green al Ethernet, M12 male connector, D-coded, male connector, straight, cable length: 2 m, UR, green al Ethernet, M12 male connector, D-coded, male connector, straight, cable length: 2 m, UR, green al Ethernet, M12 male connector, D-coded, male connector, D-coded, straight, cable length: ial: PUR, green al Ethernet, M12 male connector, D-coded, male connector, D-coded, straight, cable length: ial: TPE, turquoise al Ethernet, M12 male connector, D-coded, male connector, straight, cable length: 2 m, PE, turquoise
Technical data
Module Status LED (12)
| LED Color |
Status |
| ETH1/ETH2 Green |
On Flashing |
| Yellow |
On Flashing Off |
| BUS Green |
On Flashing |
| Red |
On Flashing |
| Green/red |
Alternating Off |
| ERR Green |
On |
| Red |
On |
| LED response |
master in the Beep network: |
| Green |
1 Hz, 250 ms off |
| Red/green |
1 Hz, 250 ms red |
| Green/red |
1 Hz, alternating |
PROFINET (11)
| Version |
2.35 |
| Addressing |
DCP |
| Conformance class |
B (RT) |
| MinCycleTime |
1 ms |
| Fast Start-Up (FSU) |
< 150 ms |
| Diagnostics |
acc. to PROFINET alarm handling |
| Topology detection |
supported |
| Automatic addressing |
supported |
| Media Redundancy Protocol (MRP) |
supported |
| System redundancy |
S2 |
| Netload class |
3 |
Digital inputs (11)
| Number of channels |
16 |
| Connectivity inputs |
M12, 5-pin |
| Input type |
NPN |
| Type of input diagnostics |
Group diagnostics |
| Switching threshold |
No specification for NPN devices |
| Low-level signal voltage |
> (supply voltage - 5 V) |
| High level signal voltage |
< (supply voltage - 11 V) |
| Low level signal current |
< 1.5 mA |
| High level signal current |
> 2 mA |
| Input delay |
2.5 ms |
| Electrical isolation |
Galvanic isolation from the fieldbus Voltage proof up to 500 VDC |
EtherNet/IP (9)
| Addressing |
acc. to EtherNet/IP specification |
| Quick Connect (QC) |
< 150 ms |
| Min. RPI |
2 ms |
| Device Level Ring (DLR) |
supported |
| Class 3 connections (TCP) |
3 |
| Class 1 connections (CIP) |
10 |
| Input Assembly Instance |
101 |
| Output Assembly Instance |
102 |
| Configuration Assembly Instance |
106 |
Digital outputs (9)
| Number of channels |
16 |
| Connectivity outputs |
M12, 5-pin |
| Output type |
NPN |
| Type of output diagnostics |
Channel diagnostics |
| Output voltage |
24 VDC from potential group |
| Output current per channel |
1.0 A, short-circuit proof, max. 2.0 A per port |
| Load type |
EN 60947-5-1: DC-13 |
| Electrical isolation |
Galvanic isolation from the fieldbus Voltage proof up to 500 VDC |
| Output delay |
1,3 ms |
Power supply (8)
| Supply voltage |
24 VDC |
| Admissible range |
18…30 VDC Max. total current 9 A per voltage group Max. total current V1 + V2 11 A |
| Voltage supply connection |
7/8″, 4-pin |
| Operating current |
V1: max. 150 mA |
| Sensor/actuator supply |
supply of ports C0-C3 from V1 short-circuit proof, 120 mA per port |
| Sensor/actuator supply |
supply of ports C4-C7 from V2 short-circuit proof, 120 mA per port |
| Electrical isolation |
Galvanic isolation of V1 and V2 voltage group Voltage proof up to 500 VDC |
| Power dissipation, typical |
≤ 10 W |
Mechanical data (8)
| Dimensions |
230,4 mm x 60,4 mm x 39 mm |
| Housing material |
PA6-GF30 |
| Housing color |
Black |
| Material screw |
303 stainless steel |
| Material label |
Polycarbonate |
| Male connector material |
Nickel-plated brass |
| Window material |
Lexan |
| Mounting |
2 mounting holes Ø 6.3 mm |
System data (7)
| Fieldbus transmission rate |
10/100 Mbps |
| Fieldbus connection technology |
2 x M12, 4-pin, D-coded |
| Protocol detection |
automatic |
| Web server |
Default: 192.168.1.254 |
| Service interface |
Ethernet via P1 or P2 |
| BEEP functionality |
supported |
| ARGEE functionality |
supported |
Ambient conditions (7)
| Ambient temperature |
-40...+70 °C |
| Storage temperature |
-40…+85 °C |
| Altitude |
max. 5000 m |
| Electromagnetic compatibility |
Acc. to EN 61131-2 |
| Shock test |
acc. to DIN EN 60068-2-27 |
| Vibration test |
Acc. to EN 60068-2-6, acceleration up to 20 g |
| Protection class |
IP65 IP67 IP69K |
CC-Link (6)
| Interface |
CC-Link IE Field Basic |
| Type |
Intelligent device station |
| Message Transmission |
yes |
| Number of occupied stations |
1 |
| IP change mechanism |
yes |
| Acyclic SLMP communication |
yes |
Modbus TCP (5)
| Addressing |
Static IP, DHCP |
| Supported function codes |
FC3, FC4, FC6, FC16, FC23 |
| Number of TCP connections |
8 |
| Input register start address |
0 (0x0000 hex) |
| Output register start address |
2048 (0x0800 hex) |
Red (5)
| PWR LED response |
parameter (PWR) at V undervoltage 2 |
| Green |
On |
| Red |
On Off |
| LED response |
parameter (PWR) at V undervoltage 2 |
| Green |
On Flashing Off |
</styleobject> (5)
| LED Color |
Status |
| LED 0 … 15 Green |
On |
| Red |
On Flashing Off |
| Process Data Mapping of the Single |
Protocols |
| For more details on the corresponding protocols |
see manual. |
Tests/approvals (4)
| Approvals and certificates |
CE UKCA ATEX zone 2/22 CCC-Ex FCC statement, UV resistant acc. to DIN EN ISO 4892-2A (2013) |
| UL Certificate |
cULus LISTED 21 W2, encl. Type 1 IND.CONT.EQ. |
| Note on ATEX/IECEx |
The Quick Start Guide with information on use in Ex areas must be observed. |
| MTTF |
125 years |
Field logic controller (FLC) (2)
| ARGEE Firmware Version |
3.2.9.0 |
| ARGEE Engineering Version |
2.0.24.0 |
Electrical data (1)
| Short-circuit protection |
yes |
Inputs/Outputs (1)
Standards/directives (1)
| Drop and topple |
Acc. to IEC 60068-2-31/IEC 60068-2-32 |
Other properties (1)
Comments (1)
Delivery time and availability
For urgent orders please ask us for the exact delivery time in advance; on request we check express shipping.
Your Benefits With Us
- Worldwide shipping of all Turck fieldbus and interface products
- Large stock levels for many products – current lead time available on request
- Terminal blocks, terminating resistors, gateways and connection cables available on request
- Fast shipping via UPS (parcel) or freight forwarder (pallets), express delivery available on request
- Extensive hands-on application know-how
- Personal advice on selecting the right component
- Resellers receive volume-based discounts on request
- Large companies, public authorities and government agencies can order on account (request via our contact form)