Product Description
Turck TBEN-S2-2RFID-4DXP Field logic controller
The Turck TBEN-S2-2RFID-4DXP is a field logic controller. Signal type digital output, Digital input/output, Digital input, 6 channels, fieldbus EtherNet/IP, Modbus TCP, PROFINET, protection class IP65/IP67/IP69K, connection via m12, ambient temperature from -40 °C. Ident no. 6814029, EAN 4047101310252.
Features
- PROFINET device, EtherNet/IP device or Modbus TCP server
- PROFINET S2 system redundancy
- Integrated Ethernet switch
- Supports 10 Mbps/100 Mbps
- Fibre-glass reinforced housing
- Shock and vibration tested
- Fully potted module electronics
- Protection classes IP65, IP67, IP69K
- ATEX zone 2/22
- CCC-Ex
- Up to 128 bytes of user data per read/write cycle per channel as well as the use of fragments with 16 kilobytes of FIFO memory each
- Data interface for convenient use of the RFID functions
- Continuous HF bus mode with up to 32 HF read/write heads per channel
- 2 channels with M12 connection for RFID
- 4 universal digital channels, configurable as PNP inputs or 0.5 A outputs
- Programmable ARGEE M8 female connector, straight, 4-pin to M8 straight, 4-pin; cable length: 2 m, jacket ack; cULus approval M12 female connector, straight, 4-pin to M12 straight, 4-pin; cable length: 2 m, jacket ack; cULus approval stems — Y-splitter with cable, M12 male ht, 4-pin — 2 × M12 female connector, straight, h: 1 m, jacket material: PUR, black M12 female connector, angled, 4-pin to M12 straight, 4-pin, cable length: 2 m, jacket ack; cULus approval al Ethernet, M8 male connector, straight to ector, straight, cable length: 2 m, jacket een al Ethernet, extension cable, M8 male ht to M8 male connector, straight, cable length: ial: PUR, green M12 female connector, straight to M12 male ht, cable length: 2 m, jacket material: PUR, M12 female connector, straight to M12 male ht, cable length: 2 m, jacket material: PUR, pplications in the food industry, M12 male ht to M12 female connector, straight, cable et material: PPEDEM, white, stainless steel sor cordset, extension cable, M12 female ht, 5-pin, M12 male connector, straight, 5-pin, le length 2 m, cable jacket PVC, yellow, other
Technical data
Power supply (11)
| Supply voltage |
24 VDC |
| Admissible range |
18…30 VDC Gesamtstrom max. 4A per voltage group; Gesamtstrom V1 + V2 max. 5,5 A at 70°C per module |
| Voltage supply connection |
2 x M8, 4-pin, A-coded |
| Operating current |
V1: max. 120 mA V2: max. 30 mA |
| Nominal current from module bus |
≤ 30 mA |
| RFID supply V AUX 1 |
slots C0-C1 aus V1 short-circuit proof, 1,2 A ≤ 55 °C, 55 °C < 0,5 A ≤ 70 °C per channel |
| Sensor/actuator supply |
supply slots C2-C3 aus V2 short-circuit proof, 0,14 A ≤ 55 °C, 55 °C < 0,05 A ≤ 70 °C |
| Electrical isolation |
Galvanic isolation of V1 and V2 voltage group Voltage proof up to 500 VDC |
| Power dissipation, typical |
≤ 2 W |
| Nominal current from field supply |
≤100 mA |
| Sensor supply |
Output current per channel, 2.0 A, short-circuit proof, max. 4.0 A per port |
Digital inputs (11)
| Number of channels |
4 |
| Connectivity inputs |
M12, 5-pin |
| Input type |
PNP |
| Type of input diagnostics |
Channel diagnostics |
| Switching threshold |
EN 61131-2 type 3, PNP |
| Low-level signal voltage |
< 5 V |
| High level signal voltage |
> 11 V |
| Low level signal current |
< 1.5 mA |
| High level signal current |
> 2 mA |
| Input delay |
0.05 ms |
| Electrical isolation |
Galvanic isolation from the fieldbus Voltage proof up to 500 VDC |
PROFINET (9)
| Addressing |
DCP |
| Conformance class |
B (RT) |
| MinCycleTime |
1 ms |
| Fast Start-Up (FSU) |
< 500 ms |
| Diagnostics |
acc. to PROFINET alarm handling |
| Topology detection |
supported |
| Automatic addressing |
supported |
| Media Redundancy Protocol (MRP) |
supported |
| System redundancy |
S2 |
Digital outputs (9)
| Number of channels |
4 |
| Connectivity outputs |
M12, 5-pin |
| Output type |
PNP |
| Type of output diagnostics |
Channel diagnostics |
| Output voltage |
24 VDC aus potential group V2 |
| Output current per channel |
0.5 A, short-circuit proof |
| Simultaneity factor |
1 (0,03 >55°C) |
| Load type |
EN 60947-5-1: DC-13 |
| Electrical isolation |
Galvanic isolation from the fieldbus Voltage proof up to 500 VDC |
EtherNet/IP (8)
| Addressing |
acc. to EtherNet/IP specification |
| Quick Connect (QC) |
< 500 ms |
| Device Level Ring (DLR) |
supported |
| Class 3 connections (TCP) |
3 |
| Class 1 connections (CIP) |
10 |
| Input Assembly Instance |
103 |
| Output Assembly Instance |
104 |
| Configuration Assembly Instance |
106 |
Ambient conditions (7)
| Ambient temperature |
-40...+70 °C |
| Storage temperature |
-40…+85 °C |
| Altitude |
max. 5000 m |
| Electromagnetic compatibility |
Acc. to EN 61131-2 |
| Shock test |
acc. to DIN EN 60068-2-27 |
| Vibration test |
Acc. to EN 60068-2-6, acceleration up to 20 g |
| Protection class |
IP65 IP67 IP69K |
System data (6)
| Transmission rate Ethernet |
10/100 Mbps |
| Connection technology Ethernet |
2 x M8, 4--pin, D-coded |
| Protocol detection |
automatic |
| Web server |
Default: 192.168.1.254 |
| Service interface |
Ethernet via P1 or P2 |
| ARGEE functionality |
supported |
RFID (6)
| Number of channels |
2 |
| Connectivity |
M12 |
| Power supply |
1,2 A ≤ 55 °C, 55 °C < 0,5 A ≤ 70 °C per channel, short-circuit proof |
| Operation per channel |
1x HF or UHF Schreib-Lese-Kopf, to zu 32 busfähige HF Schreib-Lese- Köpfe with Endung /C53 (ggf. zusätzliche Spannungseinspeisung required) |
| RFID data interface |
HF and UHF |
| Cable length |
max. 50 m |
Mechanical data (6)
| Dimensions |
144 mm x 32 mm x 32 mm |
| Housing material |
PA6-GF30 |
| Housing color |
Black |
| Material label |
Polycarbonate |
| Male connector material |
Nickel-plated brass |
| Mounting |
2 fixing holes, Ø 4.6 mm |
Modbus TCP (5)
| Addressing |
Static IP, BOOTP, DHCP |
| Supported function codes |
FC1, FC2, FC3, FC4, FC6, FC15, FC16, FC23 |
| Number of TCP connections |
8 |
| Input register start address |
0 (0x0000 hex) |
| Output register start address |
2048 (0x0800 hex) |
Tests/approvals (4)
| Approvals and certificates |
CE and UKCA FCC statement, UV-beständig acc. to DIN EN ISO 4892-2A (2013) |
| UL Certificate |
cULus LISTED 21 W2, encl. Type 1 IND.CONT.EQ. |
| Note on ATEX/IECEx |
The Quick Start Guide with information on use in Ex areas must be observed. |
| MTTF |
179 years acc. to SN 29500 (Ed. 99) 20 °C |
Outputs (3)
| Cable length |
50 m |
| Number of channels |
2 |
| Simultaneity factor |
1 (0,03 > 55 °C) |
Field logic controller (FLC) (2)
| ARGEE Firmware Version |
3.3.5.0 |
| ARGEE Engineering Version |
2.0.26.0 |
Inputs/Outputs (2)
| Number of channels |
6 |
| Electrical isolation |
Electronics and field level isolated via optocouplers |
Electrical data (1)
| Short-circuit protection |
yes |
Cable (1)
Standards/directives (1)
| Drop and topple |
Acc. to IEC 60068-2-31/IEC 60068-2-32 |
Other properties (1)
Comments (1)
Delivery time and availability
For urgent orders please ask us for the exact delivery time in advance; on request we check express shipping.
Your Benefits With Us
- Worldwide shipping of all Turck fieldbus and interface products
- Large stock levels for many products – current lead time available on request
- Terminal blocks, terminating resistors, gateways and connection cables available on request
- Fast shipping via UPS (parcel) or freight forwarder (pallets), express delivery available on request
- Extensive hands-on application know-how
- Personal advice on selecting the right component
- Resellers receive volume-based discounts on request
- Large companies, public authorities and government agencies can order on account (request via our contact form)