Product Description
Turck TBEN-S2-4AI Field logic controller
The Turck TBEN-S2-4AI is a field logic controller. Signal type analog input, Temperature, fieldbus CC-Link IE Field Basic, EtherNet/IP, Modbus TCP, PROFINET, for Zone 2, Zone 22, transmission rate 10/100 Mbit/s, protection class IP65/IP67/IP69K, connection via m12, ambient temperature from -40 °C. Ident no. 6814025, EAN 4047101309249.
Features
- PROFINET device, EtherNet/IP device, Modbus TCP server, CC-Link IE field basic
- Integrated Ethernet switch
- Supports 10 Mbps/100 Mbps
- 2 × M8, 4-pin, Ethernet fieldbus connection
- PROFINET S2 system redundancy
- Fibre-glass reinforced housing
- Shock and vibration tested
- Fully potted module electronics
- Protection classes IP65, IP67, IP69K
- 4-pin M8 male connector for power supply
- ATEX zone 2/22
- CCC-Ex
- Each channel is freely selectable for voltage, current, RTD, resistance or thermocouple
- Measuring ranges:
- Voltage: ±500 mV, ±100 mV, ±50 mV, ±1 V, 0/1–5 V, ±10 V, 0/2–10 V
- Current: 0/4–20 mA, ±20 mA
- RTD: PT100, NI100, PT200, PT500, PT1000, NI1000
- Resistance: 0–100 Ω/400 Ω/2 kΩ/4 kΩ
- Thermocouples: Type B, C, E, G, J, K, N, R, S, T
- Inputs differential or common reference
- Programmable ARGEE Description Ethernet link (100 Mbps) Ethernet communication (100 Mbps) Ethernet link (10 Mbps) Ethernet communication (10 Mbps) No Ethernet link Active connection to a master Steady flashing: Ready Sequence of 3 flashes in 2 seconds: FLC/ARGEE active IP address conflict or Restore Mode or Modbus timeout Blink/Wink command active Waiting for assignment of an IP address, DHCP or BootP Power off No diagnostics available Diagnostics available Undervoltage diagnosis response is parameter dependent V1 power supply OK V1 power supply off or V1 undervoltage Description Input active ) Current: Wire-break at the input Measuring range exceeded Overcurrent port supply VAUX1 Input inactive Input active ) Wire-break Measured value out of range RTD: Short-circuit Input inactive Input active ) Wire-break Measured value out of range Cold junction error Input inactive t Bit Bit Bit Bit Bit Bit 5 4 3 2 1 0 0 LSB 1 LSB 2 LSB 3 LSB FL OFL WBR V1AOLULVE RTDSCCJE FL OFL WBR V1AOLULVE RTDSCCJE DIAG t Bit Bit Bit Bit Bit Bit 5 4 3 2 1 0 DIAG 0 LSB 1 LSB 2 LSB 3 LSB FL OFL WBR V1AOLULVE RTDSCCJE FL OFL WBR V1AOLULVE RTDSCCJE 3 Bit 2 Bit 1 Bit 0 AOL ULVE RTDSC CJE AOL ULVE RTDSC CJE AOL ULVE RTDSC CJE AOL ULVE RTDSC CJE DIAG V1 I/O configuration error I/O-ASSISTANT Force Mode active Pin x Overcurrent (RTD only) Overcurrent supply VAUX1 Overflow Lower limit value underrun M8 female connector, straight, 4-pin to M8 straight, 4-pin; cable length: 2 m, jacket ack; cULus approval e, M8 female connector, straight, 4-pin, cable et material: PUR, black; cULus approval e, M8 female connector, angled, 4-pin, cable et material: PUR, black; cULus approval sor cordset, extension cable, M8 female ht, 4-pin, with thread, M8 male connector, th thread, cable length 2 m, cable jacket PVC, e lengths and versions available, see onnector with Pt1000 for TBEN-S2-4AI hermocouple M12 female connector, straight, 4-pin to M12 straight, 4-pin; shielded, cable length: 2 m, UR, black; cULus approval al Ethernet, used as a bridge for connecting ules; M8 male connector, straight to M8 male ht, cable length: 0.2 m, jacket material: PUR, al Ethernet, extension cable, M8 male ht to M8 male connector, straight, cable length: ial: PUR, green al Ethernet, M8 male connector, straight to ector, straight, cable length: 2 m, jacket een al Ethernet, M12 male connector, D-coded, ale connector, straight, cable length: 2 m, UR, green extension cable, M8 male connector, straight, , M8 male connector, straight, 4-pin, with cable length 2 m, cable jacket TPU, teal, other extension cable, M8 male connector, straight, , RJ45 male connector, straight, 8-pin, ength 2 m, cable jacket TPU, teal, other cable
Technical data
</styleobject> (18)
| LED Color |
Status |
| operating mode green voltage/Strom AI 0 ... 3 |
On |
| Red |
blinkt (~0.5Hz) blinkt (~4Hz) an aus |
| operating mode green RTD/Widerstand AI 0 ... 3 |
On |
| Red |
blinkt (~0.5Hz) blinkt (~4Hz) an aus |
| operating mode green Thermoelement AI 0 ... 3 |
On |
| Red |
blinkt (~0.5Hz) blinkt (~4Hz) an aus |
| Process Data Mapping of the Single |
Protocols |
| For more details on the corresponding protocols Modbus TCP Register Mapping |
see manual. |
| Reg Bit Bit Bit Bit |
Bit Bit Bit Bit Bit Bit |
| 15 14 13 12 |
11 10 9 8 7 6 |
| Inputs 0x0000Kanal 0 MSB (RO) |
channel 0 LSB |
| 0x0001Kanal 1 MSB |
channel 1 LSB |
| 0x0002Kanal 2 MSB |
channel 2 LSB |
| 0x0003Kanal 3 MSB |
channel 3 LSB |
| Diag 0x0004LLVU UFL OFL WBR LSB channel 0 MSB channel 1 |
V1AOLULVE RTDSCCJE LLVU UFL |
| LSB 0x0005LLVU UFL OFL WBR channel 2 MSB channel 3 |
V1AOLULVE RTDSCCJE LLVU UFL |
| Status 0x0006 FCE (RO) |
V1 V2 |
Analoge Inputs - operating mode voltage (12)
| Eingangsfilter |
standard, glatt, schnell, aus |
| Max. input voltage |
11,85 V |
| Lastwiderstand |
100 KΩ |
| Eingangssignalarten |
symmetrisch, symmetrisch none Masse, asymmetrisch |
| Measuring range |
0…10 V, +/-10 V, 2…10 V, 0…5 V, 1…5 V, +/-1 V +/-500 mV, +/-100 mV, +/-50 mV |
| Gleichtaktspannung |
+/- 15 V |
| Netzunterdrückung |
no, 50 Hz, 60 Hz |
| Cycle time |
4 ms |
| Grundfehlergrenze at 25 °C |
<0.1 % |
| Repeatability |
< 0,015 % |
| Temperature coefficient |
< 100 ppm/°C of MBE |
| Absoluter Messfehler (MBE) |
< 0.75 % |
Analoge Inputs - operating mode Strom (12)
| Eingangsfilter |
standard, glatt, schnell, aus |
| Max. input current |
23 mA |
| load resistance |
50 Ω |
| Eingangssignalarten |
symmetrisch, symmetrisch none Masse, asymmetrisch |
| Measuring range |
0…20 mA, 4…20 mA, +/-20 mA |
| Gleichtaktspannung |
+/- 15 V |
| Netzunterdrückung |
no, 50 Hz, 60 Hz |
| Cycle time |
4 ms |
| Grundfehlergrenze at 25 °C |
<0.1 % |
| Repeatability |
< 0,015 % |
| Temperature coefficient |
< 100 ppm/°K of MBE |
| Absoluter Messfehler (MBE) |
< 0.75 % |
PROFINET (11)
| Version |
2.35 |
| Addressing |
DCP |
| Conformance class |
B (RT) |
| MinCycleTime |
1 ms |
| Fast Start-Up (FSU) |
< 500 ms |
| Diagnostics |
acc. to PROFINET alarm handling |
| Topology detection |
supported |
| Automatic addressing |
supported |
| Media Redundancy Protocol (MRP) |
supported |
| System redundancy |
S2 |
| Netload class |
3 |
EtherNet/IP (9)
| Addressing |
acc. to EtherNet/IP specification |
| Quick Connect (QC) |
< 500 ms |
| Min. RPI |
2 ms |
| Device Level Ring (DLR) |
supported |
| Class 3 connections (TCP) |
3 |
| Class 1 connections (CIP) |
10 |
| Input Assembly Instance |
103 |
| Output Assembly Instance |
104 |
| Configuration Assembly Instance |
106 |
operating mode RTD/Widerstand (9)
| Temperatureinheit |
°Celsius, °Fahrenheit |
| Measuring range |
Pt100 -200°C..850°C, Pt100 -200°C..150°C *2) Pt200 -200°C..850°C*3)*4), Pt200 -200°C..150°C Pt500 -200°C..850°C*1), Pt500 -200°C..150°C*3)*4) Pt1000 -200°C..850°C,Pt1000 -200°C..150°C*1) Ni100 -60°C..250°C*2), Ni100 -60°C..150°C*2)*4) Ni1000 -60°C..250°C*2)*4), Ni1000 -60°C..150°C*4) 0…100Ω*2), 0…400Ω, 0…2kΩ, 0…4kΩ |
| Anschlussarten |
2-Draht, 3-Draht, 4-Draht |
| Eingangsfilter |
standard, glatt |
| Cycle time |
400 ms |
| Grundfehlergrenze at 25 °C |
< 0.2 % *1) < 0.3 % 2-Draht, *2) < 0.3 %, 3- Draht, *3) < 0.3 %, 4-Draht, *4) < 0.7 % 2- Draht |
| Repeatability |
< 0,015 % |
| Temperature coefficient |
< 100 ppm/°C of MBE |
| Absoluter Messfehler (MBE) |
< 0.85 % *1) < 0.95 % 2-Draht, *2) < 0.95 %, 3- Draht, *3) < 0.95 %, 4-Draht, *4) < 1.35 %, 2- Draht |
operating mode Thermoelement (9)
| Temperatureinheit |
°Celsius, °Fahrenheit |
| Measuring range |
Type K -270…1370°C *3), Type B 100…1820°C *2) Type E -270…1000°C *4), Type J -210…1200°C Type N -270…1300°C, Type R -50…1768°C *1) Type S -50…1768°C *1), Type T -270…400°C *3) Type C 0…2315°C, Type G 0…2315°C *5) |
| Eingangsfilter |
standard, glatt |
| Kaltstellenkompensation |
fest 23°C, Pt100, Pt1000, Kanal0 |
| Cycle time |
400 ms |
| Grundfehlergrenze at 25 °C |
< 0.1% *1) < 0.2%, *2) < 0.5%, *3) < 0.7%, *4) < 1 %, *5) < 1.6% 3, 4, 5 nur am unteren Measuring range |
| Repeatability |
< 0,015 % |
| Temperature coefficient |
< 100 ppm/°C of MBE |
| Absoluter Messfehler (MBE) |
< 0.75% *1) < 0.85%, *2) < 1.15%, *3)< 1.35%, *4) < 1.65%, *5) < 2.25% 3, 4, 5 nur am unteren Measuring range |
Module Status LED (9)
| LED Color |
Status |
| ETH1/ETH2 Green |
On Flashing |
| Yellow |
On Flashing Off |
| BUS Green |
On Flashing |
| Red |
On Flashing |
| Red/ Green |
Alternating Off |
| ERR Green |
On |
| Red |
On |
| PWR Green |
On Off |
Legend: (9)
| V2 Undervoltage |
V2 FCE |
| Cx Port x |
Px |
| DIx Digital input |
channel x DOx |
| I/ODiag I/O-Diagnostics |
liegt an |
| Diag Diagnostics |
an mind. 1 channel |
| CJE Kaltstellen-Fehler |
RTDSC |
| ULVE Oberer überschritten |
limit value V1AOL |
| WBR wire break |
OFL |
| UFL Messwert |
Unterlauf LLVU |
Analoge Inputs (8)
| Number of channels |
4 |
| Betriebsarten |
voltage, Strom, RTD, Widerstand, Thermoelement |
| Type of input diagnostics |
Channel diagnostics |
| Sensor supply |
24 VDC |
| Maximum limiting frequency analog |
<50 Hz |
| Resolution |
16 Bit |
| Measuring principle |
Sigma Delta |
| Measured-value display |
16 bit signed integer 12 bit full range left-justified |
Ambient conditions (7)
| Ambient temperature |
-40...+70 °C |
| Storage temperature |
-40…+85 °C |
| Altitude |
max. 5000 m |
| Electromagnetic compatibility |
Acc. to EN 61131-2 |
| Shock test |
acc. to DIN EN 60068-2-27 |
| Vibration test |
Acc. to EN 60068-2-6, acceleration up to 20 g |
| Protection class |
IP65 IP67 IP69K |
Input data (station -> scanner) (7)
| Status 0x0000 FCE Word |
V1 V2 |
| Inputs 0x0001Kanal 0 MSB (RO) |
channel 0 LSB |
| 0x0002Kanal 1 MSB |
channel 1 LSB |
| 0x0003Kanal 2 MSB |
channel 2 LSB |
| 0x0004Kanal 3 MSB |
channel 3 LSB |
| Diag 0x0005LLVU UFL OFL WBR LSB channel 0 MSB channel 1 |
V1AOLULVE RTDSCCJE LLVU UFL |
| LSB 0x0006LLVU UFL OFL WBR channel 2 MSB channel 3 |
V1AOLULVE RTDSCCJE LLVU UFL |
Power supply (6)
| Supply voltage |
24 VDC |
| Admissible range |
18…30 VDC Gesamtstrom max. 4A per voltage group V1 |
| Voltage supply connection |
2 x M8, 4-pin, A-coded |
| Operating current |
V1: min. 100 mA, max. 240 mA |
| Sensor/actuator supply |
supply slots C0-C3 aus V1 short-circuit proof, max 1 A per Gruppe C0-C3 |
| Electrical isolation |
Galvanic isolation of V1 and V2 voltage group Voltage proof up to 500 VDC |
System data (6)
| Fieldbus transmission rate |
10/100 Mbps |
| Fieldbus connection technology |
2 x M8, 4-pin |
| Protocol detection |
automatic |
| Web server |
Default: 192.168.1.254 |
| Service interface |
Ethernet via P1 or P2 |
| ARGEE functionality |
supported |
CC-Link (6)
| Interface |
CC-Link IE Field Basic |
| Type |
Intelligent device station |
| Message Transmission |
yes |
| Number of occupied stations |
1 |
| IP change mechanism |
yes |
| Acyclic SLMP communication |
yes |
Mechanical data (6)
| Dimensions |
144 mm x 32 mm x 32 mm |
| Housing material |
PA6-GF30 |
| Housing color |
Black |
| Material label |
Polycarbonate |
| Male connector material |
Nickel-plated brass |
| Mounting |
2 fixing holes, Ø 4.6 mm |
Modbus TCP (5)
| Addressing |
Static IP, DHCP |
| Supported function codes |
FC3, FC4, FC6, FC16, FC23 |
| Number of TCP connections |
8 |
| Input register start address |
0 (0x0000 hex) |
| Output register start address |
2048 (0x0800 hex) |
Tests/approvals (4)
| Approvals and certificates |
CE UKCA ATEX zone 2/22 CCC-Ex FCC statement, UV resistant acc. to DIN EN ISO 4892-2A (2013) |
| UL Certificate |
cULus LISTED 21 W2, encl. Type 1 IND.CONT.EQ. |
| Note on ATEX/IECEx |
The Quick Start Guide with information on use in Ex areas must be observed. |
| MTTF |
145 years acc. to SN 29500 (Ed. 99) 20 °C |
0x07 Kanal3 MSB (4)
| Diag 0x08 LLVU UFL Kanal0 |
OFL WBR V1AOL |
| Diag 0x09 LLVU UFL Kanal1 |
OFL WBR V1AOL |
| Diag 0x0A LLVU UFL Kanal2 |
OFL WBR V1AOL |
| Diag 0x0B LLVU UFL Kanal3 |
OFL WBR V1AOL |
Field logic controller (FLC) (2)
| ARGEE Firmware Version |
3.1.2.0 |
| ARGEE Engineering Version |
2.0.26.0 |
EtherNet/IP Datenmapping (2)
| Word Bit Bit Bit Bit |
Bit Bit Bit Bit Bit Bit |
| 15 14 13 12 |
11 10 9 8 7 6 |
Standards/directives (1)
| Drop and topple |
Acc. to IEC 60068-2-31/IEC 60068-2-32 |
Other properties (1)
Comments (1)
PROFINET process data (1)
| Byte Bit 7 Bit |
6 Bit 5 Bit 4 Bit |
Delivery time and availability
For urgent orders please ask us for the exact delivery time in advance; on request we check express shipping.
Your Benefits With Us
- Worldwide shipping of all Turck fieldbus and interface products
- Large stock levels for many products – current lead time available on request
- Terminal blocks, terminating resistors, gateways and connection cables available on request
- Fast shipping via UPS (parcel) or freight forwarder (pallets), express delivery available on request
- Extensive hands-on application know-how
- Personal advice on selecting the right component
- Resellers receive volume-based discounts on request
- Large companies, public authorities and government agencies can order on account (request via our contact form)