Skip to main content Skip to search Skip to navigation

Compressed air lubricator

The lubricator is the third stage of air preparation: it adds a finely metered amount of oil to the air flow and thus lubricates cylinders, valves and air tools during operation. The standard series covers sizes 30 to 90, with connections from G ¼ to G 2, bowl capacities from 40 to 600 ml and flow rates of over 15,000 l/min.

How an ewo air lubricator works

Part of the air flow creates a vacuum at the venturi, which draws oil from the bowl and releases it as a mist into the main flow. Because the mist is only produced while air is flowing, lubrication only happens when work is actually being done. The drop rate can be checked at the sight glass and readjusted during operation. For the metering to respond at all, a minimum flow rate must be reached – 47 to 170 Nl/min depending on size.

Choosing the right air lubricator

Connection and size are decisive – they determine flow rate and minimum flow. An oversized lubricator will not lubricate at all at low air demand, because the minimum flow is never reached. The bowl is available in plastic (level visible) or metal (more robust, for harsh operation). The lubricator always belongs at the end of the preparation train, downstream of filter and regulator.

Product group Connection Size Max. pressure Items
Compressed air lubricator standard G ⅛ inlet and outlet reduced, G ¼ inlet and outlet reduced, G ⅜, G ⅜ inlet and outlet reduced, G ½ Size 30, Size 40 max. 16 bar, max. 25 bar 10
Compressed air lubricator standard G ¾ inlet and outlet reduced, G 1, G 1 ¼ inlet and outlet reduced, G 1 ½ Size 55, Size 60, Size 80 max. 16 bar, max. 25 bar 12
Compressed air lubricator standard G 1 ½ inlet and outlet reduced, G 2 Size 90 max. 16 bar, max. 25 bar 4

Typical applications

  • Air tools: impact wrenches, chipping hammers, drills
  • Pneumatic cylinders and valve terminals in continuous operation
  • Vibratory and knocker conveyors
  • Systems with long pipe runs to the point of use
  • Service units as the third stage after filter and regulator

Your benefits with us

  • Worldwide shipping of all compressed air components and service units
  • Large stock levels for many products – current lead time available on request
  • Spare parts and service kits available
  • Fast shipping via UPS (parcel) or freight forwarder (pallets), express delivery available on request
  • Extensive hands-on application know-how
  • Personal advice on selecting the right component
  • Resellers receive volume-based discounts on request
  • Large companies, public authorities and government agencies can order on account (request via our contact form)

Frequently asked questions

Where in the train does the lubricator sit?

Always last: filter, then regulator, then lubricator. Ahead of the filter, the filter removes the oil again; ahead of the regulator, it contaminates its diaphragm.

How many drops per minute are right?

As a rule of thumb about 1 to 3 drops per minute at average draw-off – the tool manual is more precise. Too much oil clogs silencers and loads the exhaust air.

My lubricator does not feed although it is full.

Usually the minimum flow is not reached. Depending on size it needs 47 to 170 Nl/min before the venturi draws any oil at all. One size smaller solves the problem.

Items  21 - 26 of 26
I am already a customer.
Login for registered customers
Log in

Add product directly to the cart:

You can search by item no. or EAN/GTIN to quickly add the product to the cart.




Service & Hilfe
Service & Hilfe
Kundenservice & Support

Wir helfen und beraten Sie in allen Fragen

Kontakt
  Oberflächentechnik Seelmann e.K.
  Bauhüttenstr. 21 06847 Dessau-Roßlau Germany
  Tel: +493405407446
  Email: [email protected]
   (Mo-Fr.) 7:00 - 16:00